Fastwarm water pump and manifold install guide
A step by step guide to commissioning a Fastwarm Water Underfloor Heating Manifold and Pump.
Music from #Uppbeat (free for Creators!):
https://uppbeat.io/t/mark-july/when-i-saw-you
License code: HKNMQVJBSHII1BBQ
foreign to the installation manual for full details if in doubt please contact fastwarm technical support Mark 600 millimeters from the subfloor to the return bar of the manifold attach the isolation ball valve manifold pump set and fill and drain valves using a 22 millimeters compression to three-quarters male BSB fitting connect the flow and return pipe from the heat source a set of pipe cutter and pipe re-rounding tools are supplied with all kits this ensures a secure and clean connection using the Euro cone compression connectors apply the Euro cone nut and split Olive to the underfloor heating pipe work before adding the insert [Music] fill the system from the mains tab the boiler fill Loop must not be used drain the water into a bucket [Music] [Music] [Music] pressure test the system up to 6 bar to ensure a leak-free connection foreign adjust the flow rates for each Loop of pipe this is calculated by dividing the length of the pipe by 40 unless stated differently on the plans if you’re in any doubt about how to fully commission your underfloor heating system please call our highly experienced technical support team